FEATURES
Complete fully calibrated measurement/control system
Accurate rms-to-dc conversion from 50 Hz to 2.7 GHz
Input dynamic range of >60 dB: −52 dBm to +8 dBm in 50 Ω
Waveform and modulation independent, such as GSM/CDMA/TDMA
Linear-in-decibels output, scaled 50 mV/dB
Law conformance error of 0.5 dB
All functions temperature and supply stable
Operates from 4.5 V to 5.5 V at 24 mA from −40°C to +85°C
Power-down capability to 1.3 mW
APPLICATIONS
Power amplifier linearization/control loops
Transmitter power control
Transmitter signal strength indication (TSSI)
RF instrumentation